Air starters

default
  • Air starters - Direct: for direct starting, stopping and protection from unacceptable load of three-phase asynchronous motors.

  • Air starters - Reversible: for inclusion reversing, exclusion and overload protection of three-phase asynchronous motors.

  • Air starters - "Star / Triangle": intended to be placed under the scheme "star / triagilnik" off and overload protection of three-phase asynchronous motors.

Аir switches type P6A

Name m-ka VITELLA
Rated insulation voltage main chain V 500
secondary circuit V 380
Rated thermal current interrupted extended mode (eight-hour) main chain A 6
secondary circuit A 6
Rated voltage and frequency of the coil contactor * V 220/380
Hz 50
Setting range of thermal relay A 4 ÷ 6
Permissible power controlled motor 380V; 50Hz; 1500 min -1 in AC3 ** kW 2.2
Rated current of fuse A 10
Number of available auxiliary contacts NO / NC will
Degree of protection - IP54
Permitted section of copper wire connecting the auxiliary circuit *** 2 mm 1.5

* Data in accordance with the contract
18 ** The indicated power of controlled motor is approximate
19 *** Class of insulation of wires - no higher than "B"

Аir switches type P10A

Name m-ka VITELLA
Rated insulation voltage main chain V 500
secondary circuit V 380
Rated thermal current interrupted extended mode (eight-hour) main chain A 10
secondary circuit A 6
Rated voltage and frequency of the coil contactor * V 220/380
Hz 50
Setting range of thermal relay A 7 ÷ 10
Permissible power controlled motor 380V; 50Hz; 1500 min -1 in AC3 ** kW 4
Rated current of fuse A 20
Number of available auxiliary contacts NO / NC will
Degree of protection - IP54
Permitted section of copper wire connecting the auxiliary circuit *** 2 mm 1.5

* Data in accordance with the contract
** The indicated power of controlled motor is approximate
*** Class of insulation of wires - no higher than "B"

Аir switches type P16A

Name m-ka VITELLA
Rated insulation voltage main chain V 500
secondary circuit V 380
Rated thermal current interrupted extended mode (eight-hour) main chain A 16
secondary circuit A 6
Rated voltage and frequency of the coil contactor * V 220/380
Hz 50
Setting range of thermal relay A 12 ÷ 18
Permissible power controlled motor 380V; 50Hz; 1500 min -1 in AC3 ** kW 7.5
Rated current of fuse A 32
Number of available auxiliary contacts NO / NC will
Degree of protection - IP54
Permitted section of copper wire connecting the auxiliary circuit *** 2 mm 1.5

* Data in accordance with the contract
** The indicated power of controlled motor is approximate
*** Class of insulation of wires - no higher than "B"

Аir switches type P25A

Name m-ka VITELLA
Rated insulation voltage main chain V 500
secondary circuit V 380
Rated thermal current interrupted extended mode (eight-hour) main chain A 25
secondary circuit A 6
Rated voltage and frequency of the coil contactor * V 220/380
Hz 50
Setting range of thermal relay A 17 ÷ 25
Permissible power controlled motor 380V; 50Hz; 1500 min -1 in AC3 ** kW 11
Rated current of fuse A 50
Number of available auxiliary contacts NO / NC will
Degree of protection - IP54
Permitted section of copper wire connecting the auxiliary circuit *** 2 mm 1.5

* Data in accordance with the contract
** The indicated power of controlled motor is approximate
*** Class of insulation of wires - no higher than "B"

Starters reversible type IP 25 E

NAME measure IP 25 E
Rated voltage naizolatsiyata main chain V 500
secondary circuit V 380
Rated thermal current interrupted extended mode / eight-hour / main chain A 25
secondary circuit A 6
Rated voltage and frequency of the coil of the contactor V 220/380
Hz 50
Setting range of thermal relay A 15-25
Permissible power managed el.dvigatel- 380V; 50Hz; 1500 min, priAS3 kW 7.5 ÷ 12.5
Rated current of fuse A 40
Number of available auxiliary contacts NO / NC will
Degree of protection IP 43
Permitted section of copper wire connecting the auxiliary circuit sq. 2.5

Аir switches type P63E, P100E

NAME   measure P 63f P 100U
Rated voltage naizolatsiyata main chain V  
secondary circuit V  
Rated thermal current interrupted extended mode / eight-hour / main chain A 63 100
secondary circuit A  
Rated voltage and frequency of the coil contactor * V  
Hz  
Setting range of thermal relay A 48 ÷ 65 50 ÷ 80
60 ÷ 100
Permissible power managed el.dvigatel- 380V; 50Hz; 1500 min, priAS3 ** kW 22 ÷ 32 24 ÷ 40
30 ÷ 50
Rated current of fuse A 100 160
Number of available auxiliary contacts NO / NC  
Degree of protection  
Permitted section of copper wire connecting the auxiliary circuit *** sq. 1.5 1.5

Starters type PZT 40E

Name m-ka VITELLA
Rated insulation voltage main chain V 500
secondary circuit V 380
Rated thermal current interrupted extended mode (eight-hour) main chain A 40
secondary circuit A R2 / 8 h
Rated voltage and frequency of the coil contactor * V 220/380
Hz 50
Setting range of thermal relay A 15 ÷ 25
Permissible power controlled motor 380V; 50Hz; 1500 min -1 in AC3 ** kW 18.5
Rated current of fuse A 50
Number of available auxiliary contacts NO / NC will
Degree of protection - IP54

Starters type PZT 63E

Name m-ka VITELLA
Rated insulation voltage main chain V 500
secondary circuit V 380
Rated thermal current interrupted extended mode (eight-hour) main chain A 63
secondary circuit A R2 / 8 h
Rated voltage and frequency of the coil contactor * V 220/380
Hz 50
Setting range of thermal relay A 15 ÷ 60
Permissible power controlled motor 380V; 50Hz; 1500 min -1 in AC3 ** kW 30
Rated current of fuse A 63
Number of available auxiliary contacts NO / NC none
Degree of protection - IP54

Starters type PZT 100U

Name m-ka VITELLA
Rated insulation voltage main chain V 500
secondary circuit V 380
Rated thermal current interrupted extended mode (eight-hour) main chain A 100
secondary circuit A R2 / 8 h
Rated voltage and frequency of the coil contactor * V 220/380
Hz 50
Setting range of thermal relay A 48 ÷ 65
Permissible power controlled motor 380V; 50Hz; 1500 min -1 in AC3 ** kW 55
Rated current of fuse A 100
Number of available auxiliary contacts NO / NC none
Degree of protection - IP54

Starters type PZT 160E

Name m-ka VITELLA
Rated insulation voltage main chain V 500
secondary circuit V 380
Rated thermal current interrupted extended mode (eight-hour) main chain A 100
secondary circuit A R2 / 8 h
Rated voltage and frequency of the coil contactor * V 220/380
Hz 50
Setting range of thermal relay A 48 ÷ 65
Permissible power controlled motor 380V; 50Hz; 1500 min -1 in AC3 ** kW 55
Rated current of fuse A 100
Number of available auxiliary contacts NO / NC none
Degree of protection - IP54